Automatic calibration. The
system will automatically adjust defect detection gates and amplifier gain
settings according to signals obtained from the test standard (e.g. tube
with notches and/or wall reductions) |
 |
A-Scan capture to allow
dynamic viewing of a transient notch signal. This is particularly useful
with high speed rotary probes. |
 |
Defect Discrimination.
Sophisticated analysis facilities are available to be applied to pulse
echo results in order to reduce spurious defect indications. This analysis
can be performed at full PRF rate on all channels in real time !!
This technique allows high integrity testing without the common compromise
of reductions in production throughput due to false indications |
 |
Non Multiplexed. All
C-MAX channels in a multi channel system "fire" in parallel, (i.e. with no
multiplexing) even at the highest PRF rates (e.g. 20KHz) and up to 128
channels. This allows the Unicorn rotary probes to be used at peak
performance in terms of production throughput rate. |